Remember, ONLY the 20B has a staging relay.
Oops; I guess I forgot.
Al
If
you want to do this on a 13B installation, swap the pri & sec injector
lines at the EC2 connector or swap the injector connectors if you have
enough wire slack to do this.
-----
Original Message -----
Sent: Wednesday, December 15,
2004 12:13 PM
Subject:
[FlyRotary] Re: Injectors
Subject:
[FlyRotary] Re: Injectors
My solution
was to simply move the staging relay from the secondary power circuit to the
primary power circuit, so it runs on the secondary at low power and all 6 at
higher power (20B). Problem
solved.
This may not be a solution for every case, as my secondary injectors are not
all that far from the ports.
Hi Al, I have the same injectors like you. How
do you do the modification with the relay?
Buly;
The staging relay normally switches the power
on or off to the secondary injectors. Just wire your primary power lead
through the relay instead. Everything else remains the same.
I was about to change my wiring harness so the
I had enough length to switch primary and secondary when suddenly the light
came on (in my head), and I realized I only had to change the power lead.
Al