In a message dated 5/3/2005 10:51:17 A.M. Central Standard Time,
Sky2high@aol.com writes:
iii. L
unit power voltage tapped after sw and is either Main Bus voltage (reduced by
isolation diode) or BB voltage, depending on switch position. Post start
checklist item could be to check BB voltage.
The following is a correction to the post start checklist item and will be
the preliminary ck list.
a. Before anything, turn on the Essential Bus to power on the EPI 800
engine monitor (including voltmeter).
b. Switch on the LSE system backup battery (for L unit) and check the
voltage of the backup battery.
c. Turn on the Master Switch.
d. Switch off the Essential Bus.
e. Start the engine.
f. Switch off the backup battery.
Of course, if I had more panel room I would install a little
voltmeter. Maybe not......