Message
On mine max rich is around 1.0 volts, mids scale gives me
around 0.45-0.6 volts, low end drops off around 0.1.5 - 0.2 volts.
Thanks Ed. That is, of course, exactly what it should read.
The next step is to temporarily re-install the old mixture gauge, and
compare it to the EM-2. I will also measure the O2 sensor voltage at the
same time. I may even pick up another O2 sensor, just in
case.
Is the O2 sensor you are using a heated 3/4 wire
unit? If so I am wondering whether you might possibly have a ground loop
feeding heater voltage onto your sensor lead?
Good
thought, but it's just the cheap single wire unit that Tracy and Finn are both
using.
Thanks,
Rusty
(mourning the loss of my 6 months paid severance
vacation)
|