Buly,
If reseating the connector doesn’t
help, it may be good to check the ground continuity between the EC2 and the
airframe ground. It is possible that the amount of current needed to
trigger the ignition coils is significantly less than that needed to operate an
injector. I don’t know how much current the ignition coil signal
takes, but each injector takes about 2 amps. To be certain the ground is
good, one may need to check all the way to the ground plane on the EC2 board.
Hopefully you will have things working
before you read this.
Steve Boese