Where have others placed their sensors?
I have one on each of the runners to the housing intake ports. I bring the
three lines to a 4-way connector - 3 in and 1 out. I think measuring MAP
close to the housings in an area that has a constant volume gives the best
results. Joe Hull
Cozy Mk-IV #991 (In Phase1 Flight Test - 26 hrs flown) Redmond (Seattle), Washington
|
|