In a message dated 10/27/2005 1:34:55 PM Eastern Daylight Time,
13brv3@bellsouth.net writes:
Thanks for the
comments Lynn. One other question came to mind though. I have a
remote sump on the single rotor, so the line from the stock oil pump will
be "suction" to some extent. I believe you have a dry sump
system, so you probably have the same situation, only worse perhaps. Are
you using these Aeroquip hoses for suction as
well?
I have two short pieces of stainless braid reinforced teflon lines in dash
12 for suction to the scavenge sections. Those two pull all of the spent oil and
a bunch of air from the sump.
For the run from the tank to the pressure pump suction side, I have a piece
of 1 1/4" electrical conduit. So suction collapse is not a factor.
I would not trust the blue stuff for suction unless it is a very short run
or has a spring installed in it.
Lynn E. Hanover