 I think that makes a big difference
in
whether or not a bleed circuit is needed.  The closer to the tanks, the
less the need for it.  I had discovered a potentially fatal design flaw
and found a simple remedy.  With air in the lines, the efi pumps simply
could not overcome the back pressure from the pressure regulator until
they were well primed.

---------------------------------------------
Hi Mark,

Makes me feel better now that I understand you are returning fuel to the
tank.

What pumps are you running because the Walbro pumps seem to reprime with
or without air in the line at least under all conditions I run into.
Seems like Al G  said he has similar experience.

My pumps are about 5 feet of #6 line from the tank and maybe 12 inches
higher than the tank.