Keep in mind that the A to B copy function was not always in the EC2.
If it isn't in your instructions, it probably isn't in the unit.
Won't hurt to try this anyway just in case the "documentation control
department" here accidentally left it out of your copy.
I couldn't remember if this was an actual feature now
or if it was just one of Rusty's wish items (right after
datalogging).
Actually, I think my wish list item was to get the
EC-2 instructions in word format, so I could cut and paste this
rather than having to type it. Anyway, here is the
procedure to copy A to B.
Rusty
(don't say I never gave you anything)
1- Turn the EC-2 power off.
2- Select controller A using the controller A/B switch on the
PCM.
3- Select mode 2 with the Mode Select
switch.
4- Press and hold the Program Store
switch.
5- While
holding down the Program Store switch, turn on the power switch to the
EC-2.
6- Keep holding the Program Store switch for about 2 seconds,
then release it.
7- All programming entries which you have performed on
controller A will now be copied to controller
B.