Mailing Lijst lml@lancaironline.net Bericht #9539
Van: Micah Froese <Micah@froese.com>
Onderwerp: Re: LOP/ROP debate
Datum: Tue, 1 May 2001 15:47:00 -0400
Aan: <lancair.list@olsusa.com>
         <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
          <<  Lancair Builders' Mail List  >>
          <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
>>
There is an extensive article on LOP operations at www.gami.com/frames.htm
Look under "future series"
Could it be that those with bad experiences running LOP set their mixture in
the following order? 1. lean mixture till the first cylinder peaks. 2.
Cautiously lean 50F further.
Doing this would probably cause some of the other 5 cylinders, (or other 3
for us mortals), to be dangerously close to peak, would it not?  With a
single probed EGT it would even be more hit-or-miss.

Micah Froese

>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
LML website:   http://www.olsusa.com/Users/Mkaye/maillist.html
LML Builders' Bookstore:   http://www.buildersbooks.com/lancair

Please send your photos and drawings to marvkaye@olsusa.com.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
Inschrijven (FEED) Inschrijven (DIGEST) Inschrijven (INDEX) Uitschrijven Mailen naar Listmaster