X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Wed, 09 Jan 2008 09:13:18 -0500 Message-ID: X-Original-Return-Path: Received: from vms042pub.verizon.net ([206.46.252.42] verified) by logan.com (CommuniGate Pro SMTP 5.2c4) with ESMTP id 2637080 for lml@lancaironline.net; Wed, 09 Jan 2008 00:34:08 -0500 Received-SPF: pass receiver=logan.com; client-ip=206.46.252.42; envelope-from=tom.gourley@verizon.net Received: from jacky0da39824a ([71.111.158.160]) by vms042.mailsrvcs.net (Sun Java System Messaging Server 6.2-6.01 (built Apr 3 2006)) with ESMTPA id <0JUD00GJE3FF1IO0@vms042.mailsrvcs.net> for lml@lancaironline.net; Tue, 08 Jan 2008 23:33:19 -0600 (CST) X-Original-Date: Tue, 08 Jan 2008 21:33:11 -0800 From: "Tom Gourley" Subject: Re: [LML] Instrument panel hardware X-Original-To: "Lancair Mailing List" Reply-to: "Tom Gourley" X-Original-Message-id: <005a01c85281$1ffc0cd0$650610ac@jacky0da39824a> MIME-version: 1.0 X-MIMEOLE: Produced By Microsoft MimeOLE V6.00.2900.3198 X-Mailer: Microsoft Outlook Express 6.00.2900.3138 Content-type: multipart/alternative; boundary="----=_NextPart_000_0057_01C8523E.113DEC60" X-Priority: 3 X-MSMail-priority: Normal References: This is a multi-part message in MIME format. ------=_NextPart_000_0057_01C8523E.113DEC60 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable For an Instrument Panel with Aluminum inserts and I was told I could not = use regular steel nutplates to attach the inserts to the panel because = of interference with instruments. What do I use?=20 I've seen quite a few instrument panels that use #6 nutplates (K1000-06 = or MK1000-06) mounted in the fiberglass instrument panel frame. I don't = see why this would interfere with the instruments. Maybe if you had = several of them really close to the mag compass it might be affected a = little. Did the person who said not to use them state the specific = interference problem? Tom Gourley ------=_NextPart_000_0057_01C8523E.113DEC60 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
For an Instrument Panel = with Aluminum=20 inserts and I was told I could not use regular steel nutplates = to attach=20 the inserts to the panel because of interference with=20 instruments.    What do I use?
 
I've seen quite a few instrument panels that use #6 nutplates = (K1000-06 or=20 MK1000-06) mounted in the fiberglass instrument = panel frame.  I=20 don't see why this would interfere with the instruments.  Maybe if = you had=20 several of them really close to the mag compass it might be = affected a=20 little.  Did the person who said not to use them state the specific = interference problem?
 
Tom Gourley
 
 
------=_NextPart_000_0057_01C8523E.113DEC60--