X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Fri, 24 Feb 2006 21:44:56 -0500 Message-ID: X-Original-Return-Path: Received: from computan.computan.on.ca ([209.5.80.10] verified) by logan.com (CommuniGate Pro SMTP 5.0.8) with ESMTP id 997409 for lml@lancaironline.net; Fri, 24 Feb 2006 21:05:03 -0500 Received-SPF: none receiver=logan.com; client-ip=209.5.80.10; envelope-from=keighan@computan.on.ca Received: from glemat9p02abp5 (usr02098.computan.on.ca [209.5.86.98]) by computan.computan.on.ca (8.12.10/8.12.10) with SMTP id k1P24IWK013618 for ; Fri, 24 Feb 2006 21:04:18 -0500 (EST) X-Original-Message-ID: <012b01c639af$cb14dd00$625605d1@glemat9p02abp5> From: "Scott & Glema" X-Original-To: "Lancair Mailing List" Subject: Hydraulic pump X-Original-Date: Fri, 24 Feb 2006 21:04:15 -0500 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0126_01C63985.DE66A3E0" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 6.00.2800.1437 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1441 This is a multi-part message in MIME format. ------=_NextPart_000_0126_01C63985.DE66A3E0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable I've just run my gear up and down on my LIV for the first time and I = have a couple of questions. 1. Is the pump supposed to make a very high pitch squeal? If not what would cause it? The sound is almost unbearable. The fluid tank was 3/4 full before priming and was about 1/2 full after. =20 2. The main gear don't go up and down together. The left gear is always first up followed closely by the right. Coming down the left goes down and locked even before the right leaves the wheel well. Should both of the mains be going up and down=20 together. 3. The pump runs for about 10 - 15 seconds after the gear is up. 4. The flap accuator is very touchy in the off positon. Wiggling seems to help keeping the flaps up and to stop them from creeping back down.=20 Any advice would be greatly appreciated. Scott Keighan =20 LIV ------=_NextPart_000_0126_01C63985.DE66A3E0 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
I've just run my gear up and down on = my  LIV=20 for the first time and I have
a couple of questions.
 
1.  Is the pump supposed to make a = very high=20 pitch squeal?
If not what would cause it?  The = sound is=20 almost unbearable.
The fluid tank was 3/4 full before = priming and=20 was about 1/2
full after. 
 
2. The main gear don't go up and down=20 together.  The left gear
is always first up followed closely by = the=20 right.  Coming down
the left goes down and locked even = before the right=20 leaves the
wheel well.  Should both of = the mains be=20 going up and down
together.
 
3. The pump runs for about 10 - 15 = seconds after=20 the gear is up.
 
4. The flap accuator is very touchy in = the off=20 positon.  Wiggling
seems to help keeping the flaps up and = to stop them=20 from
creeping back down. 
 
Any advice would be greatly=20 appreciated.
 
 
Scott Keighan  
 
LIV
 
 