Return-Path: Sender: (Marvin Kaye) To: lml Date: Fri, 09 Aug 2002 08:10:13 -0400 Message-ID: X-Original-Return-Path: Received: from out016.verizon.net ([206.46.170.92] verified) by logan.com (CommuniGate Pro SMTP 4.0b6) with ESMTP id 1685023 for marv@lancaironline.net; Fri, 09 Aug 2002 00:37:52 -0400 Received: from flyingnut ([4.46.206.82]) by out016.verizon.net (InterMail vM.5.01.05.09 201-253-122-126-109-20020611) with SMTP id <20020809043752.RSSK9318.out016.verizon.net@flyingnut> for ; Thu, 8 Aug 2002 23:37:52 -0500 X-Original-Message-ID: <000a01c23f5d$f07e1b60$6401a8c0@dslverizon.net> From: "res18fcm" X-Original-To: Subject: Re: Legacy strobe power and filter locations X-Original-Date: Thu, 8 Aug 2002 21:33:41 -0700 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0007_01C23F23.43D47EC0" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 5.50.4807.1700 X-MimeOLE: Produced By Microsoft MimeOLE V5.50.4807.1700 This is a multi-part message in MIME format. ------=_NextPart_000_0007_01C23F23.43D47EC0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable "Best location for Whelen strobe power supply?" I'm planning to put mine in the front of the center section wing root, = behind the access panels in the forward load pads. (These are the small = panels with the cylindrical pockets in them, the ones the manual says = can be used to store smoke hoods.) My friend put his there and it's = worked well. They're out of the way but easy to get at if needed. As for a gas filter, I'm planning a gascolator on the engine side of the = firewall, down low, with a cooling shroud. The hydraulic filter might = be a good topic to persue at the fly-in next month. Tom Gourley tom.gourley@verizon.net Banks, OR L2K #122 ------=_NextPart_000_0007_01C23F23.43D47EC0 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
"Best location for Whelen strobe power=20 supply?"
 
I'm planning to put mine in the front = of=20 the center section wing root, behind the access panels in the = forward=20 load pads.  (These are the small panels with the cylindrical = pockets in=20 them, the ones the manual says can be used to store smoke hoods.)  = My=20 friend put his there and it's worked well.  They're out of the way = but easy=20 to get at if needed.
 
As for a gas filter, I'm = planning a gascolator=20 on the engine side of the firewall, down low, with a cooling = shroud.  The=20 hydraulic filter might be a good topic to persue at the fly-in next=20 month.
 
Tom Gourley
tom.gourley@verizon.net
Banks, OR
L2K #122
 
------=_NextPart_000_0007_01C23F23.43D47EC0--