>>A Comment,  That ELT held on the sidewall with one bid will not be 
sufficient to withstand a 20-30 G deceleration. 
<SNIP> 
 
I suppose I should have described the mount and installation better. Both 
bond flanges of the aluminum frame are 10" long x 1.5" wide with lightening 
holes for bonding to the sidewall and floor. The lightening holes were 
floxed and one bid of cloth was layed over the flox and overlapped onto the 
sidewall. An additional layer of cloth was added to each corner for stress 
concentration factors. This provides area and even at a load of 30gs x 5 lbs 
=150 lbs / ~15"^2 bond area = 10psi. the aluminum flange was also beaded and 
flared for additional strength. I also over proof tested this frame per 
instructions for deflection and load. A push-down-with-your-hands estimate 
is that it would hold over 300lbs. 
 
 
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 