Steve,
My thermostat hole is plugged and have a #30 hole drilled through the plug. Bobby
Sent from my iPad
On Dec 26, 2017, at 9:18 PM, Stephen Izett stephen.izett@gmail.com <flyrotary@lancaironline.net> wrote:
Merry Christmas to all
I’m still troubleshooting our cooling system.
Renesis 4 port in Glasair Super II RG
We removed the thermostat, and plugged the whole between the in and out circuit with a threaded plug.
I think I read someone saying there should be a hole in that plug, which I take it was to let air our of the inlet side of the pump.
On a picture of the front housing I think I can see a hole in the top of the pump impeller housing that might perform this function.
Can anyone comment?
Thanks
Steve Izett
Perth Western Australia
--
Homepage: http://www.flyrotary.com/
Archive and UnSub: http://mail.lancaironline.net:81/lists/flyrotary/List.html
|
|