Mailing List flyrotary@lancaironline.net Message #60839
From: Tracy <rwstracy@gmail.com>
Subject: Re: [FlyRotary] EC2 wiring question
Date: Fri, 21 Mar 2014 11:05:54 -0400
To: Rotary motors in aircraft <flyrotary@lancaironline.net>
Hi Charlie,
  Latest version of installation guide was changed to all 22ga wire but 24ga is fine for everything except power,  injector return and injector driver lines.

Tracy Sent from my iPad

On Mar 21, 2014, at 11:00, Charlie England <ceengland7@gmail.com> wrote:

Q for Tracy:

My EC-2 instructions specify 20AWG & 22AWG wire. Any reason to not use 24AWG wire on the low current (signal) lines? I've got a full roll of 24AWG, & with a 5A rating and short runs, it would seem to be fine for signal lines. My bundles will be smaller and I might even save an ounce. :-)

Thanks,

Charlie

--
Homepage:  http://www.flyrotary.com/
Archive and UnSub:   http://mail.lancaironline.net:81/lists/flyrotary/List.html
Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster