Bulent Aliev wrote:
Al,
I have two EC2's. Bob White sent me his to test against mine. The NOP is flashing on both and A/B processors too.
Just a shot in the dark, but you said you've buzzed the wires to verify they're all connected. Have you buzzed them to verify that none are grounded to a neighbor? I like to put my meter on the diode test so that it beeps whenever it shorts. Then I pick up each pin individually and slide the other probe across all the other pins to verify that I haven't bridged something somewhere.
|
|