So
far, Al's controller is the only one that I know of that has had this
problem. Not unit specific because it has happened on 3 different EC2s in
Al's plane so I have concluded that it is something unique to his
installation. I'd like to get to the bottom of it and any other
reports would be helpful.
Small point, Tracy, but we’ve actually
seen the issues on just 2 EC2 units; the original and the current. But even then
it would certainly suggest it is not specific a given ‘box’. The
one intermediate box in which you had switched the internal connection on the
temp sensor, to save me the trouble, never got past finding the transmit RFI problem,
so never determined whether there was corruption of settings. The connecting
PCM and EM2 are still the same.
The really puzzling (and frustrating) thing
is that we have had the scope on every pin on the EC2 connector, and, after
eliminating a couple potential noise issues, we saw nothing that could explain
why it is happening. So the investigation continues. If someone else sees
similar behavior, it might provide a clue.
Al (perfect weather conditions today,
and the plane was ready to go – but at the last moment I decided I wasn’t.
Guess I’m fighting some holiday bug. Bummer.)