Mailing List flyrotary@lancaironline.net Message #21629
From: WALTER B KERR <jbker@juno.com>
Subject: Re: [FlyRotary] Re: EC2 redundancy
Date: Mon, 9 May 2005 09:23:02 -0400
To: <flyrotary@lancaironline.net>
Jim S wrote:If we've mostly agreed that we're sizing fuse/CB to protect
the wire and not the component, what would be the point of redundant feeds to a common power line inside the box?
What failure mode are we protecting against with this scheme? ... Jim S.
-----------------------------------------------------

We are protecting against a defective fuse such as Paul had or a direct
short in one of the lines that has blown a good fuse. The other line will
continue to operate the EC2 if you have diodes to prevent a backfeed. Of
course you wish to separate the wires to prevent the burning one from
destroying the 2nd one.

Bernie
Subscribe (FEED) Subscribe (DIGEST) Subscribe (INDEX) Unsubscribe Mail to Listmaster