|
<<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
<< Lancair Builders' Mail List >>
<<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
>>
This is probably not related to the current discussion but there are at least two
known errors in the installation manual (rev F.) This manual came with my system in
December '99...
1. On page 12, the note at the bottom of the page below Oil System Wiring 1.3.3,
only applies to oil pressure...NOT OIL TEMPERATURE.
2. On page 21, note 2. at the bottom of the page...first sentence is correct but
all of the second sentence relating to jumpers is garbage (in error)...
Apparently, REV G is now the currrent version of the namual.
Why nobody elected to inform me is another matter!
According to the factory, low voltage is not the cause of erroneous readings. If
the unit sees 10 volts, it's happy, otherwise, it shuts off.
Angier Ames
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
LML website: http://www.olsusa.com/Users/Mkaye/maillist.html
LML Builders' Bookstore: http://www.buildersbooks.com/lancair
Please send your photos and drawings to marvkaye@olsusa.com.
>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>
|
|