Hello there,
I am looking for some advice. I had the plane (TSIO 550)
out of annual about 15 minutes into the air and the TIT 1, TIT 2 and P temps on
the VM1000 all read 0000. The EGTs and the CHTs on all cylinders work fine as
do the engine instruments. I don’t think this sounds like a single probe
failure, but why that pattern? Any ideas would be appreciated. The local
avionics shop isn’t up to speed and before I get it torn apart, if
someone had this experience, I’d appreciate hearing about what you did.
The unit is 12 years old and has 1200TT.
Michael Smith