EII says probes can't fail.

Sent using my iPhone.
Danny

On May 13, 2013, at 12:31 PM, "William A. Hogarty" <billhogarty@gmail.com> wrote:

Does anyone know a method to test a VM probe in the wing when the wing has been removed from the ,plane.
 
Also, assuming the probe is faulty, where to find a replacement????
 
Thanks, Bill Hogarty


On Mon, May 13, 2013 at 4:50 AM, Greenbacks, UnLtd. <N4ZQ@verizon.net> wrote:
Danny, their /4 changes the base sensor count before calibration and depending on the length of your probes, there should be no need to install this device between the probe and FLC.
I have 2 4' Vision Micro Systems probes in my wings and they interface seamlessly with my EI MVP-50. Their /4 device is
required in line when the probe is short as in my header tank...16".

Angier Ames
N4ZQ
--