X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Thu, 16 Aug 2007 21:19:17 -0400 Message-ID: X-Original-Return-Path: Received: from bay0-omc2-s3.bay0.hotmail.com ([65.54.246.139] verified) by logan.com (CommuniGate Pro SMTP 5.1.11) with ESMTP id 2265479 for lml@lancaironline.net; Wed, 15 Aug 2007 23:24:32 -0400 Received-SPF: pass receiver=logan.com; client-ip=65.54.246.139; envelope-from=randystuart@hotmail.com Received: from hotmail.com ([65.55.139.19]) by bay0-omc2-s3.bay0.hotmail.com with Microsoft SMTPSVC(6.0.3790.2668); Wed, 15 Aug 2007 20:23:55 -0700 Received: from mail pickup service by hotmail.com with Microsoft SMTPSVC; Wed, 15 Aug 2007 20:23:55 -0700 X-Original-Message-ID: Received: from 68.183.63.186 by BAY134-DAV9.phx.gbl with DAV; Thu, 16 Aug 2007 03:23:55 +0000 X-Originating-IP: [68.183.63.186] X-Originating-Email: [randystuart@hotmail.com] X-Sender: randystuart@hotmail.com From: "Randy" X-Original-To: "Lancair Mailing List" References: Subject: Vision Micro Problem X-Original-Date: Wed, 15 Aug 2007 20:23:57 -0700 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_01C1_01C7DF7A.35409EA0" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 6.00.2900.3138 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.3138 X-OriginalArrivalTime: 16 Aug 2007 03:23:55.0817 (UTC) FILETIME=[E092C190:01C7DFB4] X-Original-Return-Path: randystuart@hotmail.com This is a multi-part message in MIME format. ------=_NextPart_000_01C1_01C7DF7A.35409EA0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Has anyone had a problem with their VisionMicro 1000 MAP sensor? Mine is = reading very very slow. It's solid and I checked all the wiring. I = connected a vacuum pump to it today and when I run the pressure down the = VM 1000 will start to read lower and lower but it takes about 10 seconds = for it to change a very small amount. EX: from 27 to 10 might take 4 ~ 5 = minutes, and back again the same.=20 It seems like the MAP sensor is reading right but takes forever to = change... Anyone see this, or fixed the same problem? Thanks, Randy Stuart LNC2 ------=_NextPart_000_01C1_01C7DF7A.35409EA0 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
Has anyone had a problem with = their=20 VisionMicro 1000 MAP sensor? Mine is reading very very slow. It's solid = and I=20 checked all the wiring. I connected a vacuum pump to it today and when I = run the=20 pressure down the VM 1000 will start to read lower and lower but it = takes about=20 10 seconds for it to change a very small amount. EX: from 27 to 10 might = take 4=20 ~ 5 minutes, and back again the same.
It seems like the MAP sensor = is reading=20 right but takes forever to change... Anyone see this, or fixed the same=20 problem?
Thanks,
Randy = Stuart
LNC2
------=_NextPart_000_01C1_01C7DF7A.35409EA0--