X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: Sender: To: lml@lancaironline.net Date: Sat, 18 Mar 2006 22:38:04 -0500 Message-ID: X-Original-Return-Path: Received: from smtp102.sbc.mail.mud.yahoo.com ([68.142.198.201] verified) by logan.com (CommuniGate Pro SMTP 5.0.8) with SMTP id 1038650 for lml@lancaironline.net; Sat, 18 Mar 2006 20:29:07 -0500 Received-SPF: none receiver=logan.com; client-ip=68.142.198.201; envelope-from=elippse@sbcglobal.net Received: (qmail 2704 invoked from network); 19 Mar 2006 01:28:24 -0000 Received: from unknown (HELO Computerroom) (elippse@sbcglobal.net@71.157.178.61 with login) by smtp102.sbc.mail.mud.yahoo.com with SMTP; 19 Mar 2006 01:28:24 -0000 X-Original-Message-ID: <007301c64af4$71140190$3db29d47@Computerroom> From: "Paul Lipps" X-Original-To: Subject: cooling problem X-Original-Date: Sat, 18 Mar 2006 17:28:33 -0800 MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0070_01C64AB1.61BF9490" X-Priority: 3 X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook Express 6.00.2900.2180 X-MIMEOLE: Produced By Microsoft MimeOLE V6.00.2900.2180 This is a multi-part message in MIME format. ------=_NextPart_000_0070_01C64AB1.61BF9490 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Connections for these probes are very susceptible to voltage generation = with dissimilar metals. Be sure that any other wire connections that are = made to the probe wires are made on both wires identically. Also, if a = switch has been installed to monitor each cylinder on a single = indicator, you must switch both wires and not switch just one wire and = gang the others together. This introduces big errors. Before you start = chasing baffling and such, be sure your CHT indication is calibrated! ------=_NextPart_000_0070_01C64AB1.61BF9490 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable
Connections for these probes are very = susceptible to=20 voltage generation with dissimilar metals. Be sure that any other wire=20 connections that are made to the probe wires are made on both wires = identically. Also, if a switch has been installed to monitor each = cylinder on a=20 single indicator, you must switch both wires and not switch just one = wire and=20 gang the others together. This introduces big errors. Before you start = chasing=20 baffling and such, be sure your CHT indication is=20 calibrated!
------=_NextPart_000_0070_01C64AB1.61BF9490--