Which wire was shorted to what?
I have never ohm'ed igniter coils. Input (control) is 0 to 5V I�
believe.
Not sure what the outputs should show when ohmed to ground.
Finn
On 9/2/2020 8:17 PM, DAVID BARKER
david_barker@msn.com wrote:
Dear Kelly,
I have been following the fly rotary letters and comments for
awhile. Not sure what I am suppose to do to post my own request.
Perhaps you can assist me. I have a 13b with the Tracy Crooks
PSRU and the EC2 engine controller. The problem is I think I
have mortally wounded the EC2 controller and perhaps the igniter
coils as well. (Wire shorted )
All 4 igniter coils now appear to be open circuits (infinite
ohms) and the EC2 is not pulsing the coil signals are now ON
constantly. Is their anyone doing repair work on the EC2
controllers (serial #283 AX) has backup crank sensor. �Pulses
for the injectors are also missing.�
I would greatly appreciate any referral.
Dave Barker
EAA 587700
Sent from my