Concerned with my broken ground wire, I examined where the wire broke, right at the connection. I crimped some test wire with the same wire, terminators and crimps and what I have determined is that I MUST have crimped the 16 gage wire with the wrong size crimp (20gage crimp) and the smaller size crimp cut the the thicker wire to a point of failure. The test crimps I did with the smaller crimps on the larger wire produced the same visual result as what failed. I have done so many crimps of 20 gage wire, I am guessen' that my motor memory just went to the red crimp. <embarrassed sigh>.
Just a small data point.