X-Virus-Scanned: clean according to Sophos on Logan.com Return-Path: <13brv3@bellsouth.net> Received: from imf24aec.mail.bellsouth.net ([205.152.59.72] verified) by logan.com (CommuniGate Pro SMTP 4.3c5) with ESMTP id 932113 for flyrotary@lancaironline.net; Wed, 04 May 2005 08:38:12 -0400 Received-SPF: pass receiver=logan.com; client-ip=205.152.59.72; envelope-from=13brv3@bellsouth.net Received: from rd ([65.6.194.9]) by imf24aec.mail.bellsouth.net (InterMail vM.5.01.06.11 201-253-122-130-111-20040605) with ESMTP id <20050504123727.VGGY2434.imf24aec.mail.bellsouth.net@rd> for ; Wed, 4 May 2005 08:37:27 -0400 From: "Russell Duffy" <13brv3@bellsouth.net> To: "'Rotary motors in aircraft'" Subject: RE: [FlyRotary] Re: twin distributor cover was Re: 12A front cover Date: Wed, 4 May 2005 07:37:41 -0500 Message-ID: <03f101c550a6$1006c700$6101a8c0@rd> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_03F2_01C5507C.2730BF00" X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.6626 Importance: Normal X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2900.2527 In-Reply-To: This is a multi-part message in MIME format. ------=_NextPart_000_03F2_01C5507C.2730BF00 Content-Type: text/plain; charset="us-ascii" Content-Transfer-Encoding: quoted-printable Yes that's the cover I have, It has 2 problems. One you cannot use a = belt driven water pump( as you can see in the photo)you have to have a thin adaptor or drill & tap the top of the housing to fit fittings for a EWP, secondly the gasket shape appears to be the same but one cover mounting = bolt is in a different spot (But workable).=20 Hi Georges, Thanks for the extra info. Pity it doesn't just bolt up and work = without any mods, but that would just be too much to hope for I guess. All in = all, it's probably easier to use two of the later style pickups, rather than = two CAS's. =20 =20 Cheers, Rusty =20 ------=_NextPart_000_03F2_01C5507C.2730BF00 Content-Type: text/html; charset="us-ascii" Content-Transfer-Encoding: quoted-printable Message

Yes that's the cover I have, It has 2 problems. One = you cannot=20 use a belt driven water pump( as you can see in the photo)you have to = have a=20 thin adaptor or drill & tap the top of the housing to fit fittings = for a=20 EWP, secondly the gasket shape appears to be the same but one cover = mounting=20 bolt is in a different spot (But workable).

Hi Georges,

Thanks for the extra info.  = Pity it=20 doesn't just bolt up and work without any mods, but that would just be = too much=20 to hope for I guess.  All in all, it's probably easier to use two = of the=20 later style pickups, rather than two CAS's. 
 
Cheers,
Rusty
 
------=_NextPart_000_03F2_01C5507C.2730BF00--