Thanks for that info, Perry. Paul
Conner
----- Original Message -----
Sent: Saturday, February 12, 2005 8:12
AM
Subject: [FlyRotary] Vapor Lock
Hi, Perry....One question....Does
your unburned fuel (from the fuel rail) go back into your sump tank
also? Or do you return the unused fuel to one of your fuel
tanks? If I were returning fuel to one of the main tanks, I would think
that venting the sump would be appropriate, but since I am sending fuel undere
pressure back into the sump tank, I am concerned that once the sump tank is
full, the additional fuel pumped back into the sump tank would take the path
of least resistance....out the vent instead of back up the fuel line into the
tank? Thanks for your input. Paul Conner
One other comment Paul: the fuel return from the fuel rail is
not pressurized. The pressure regulator maintains HP on the fuel rail side,
but the fuel return output back to the sump is not under high
pressure.