Mailing List lml@lancaironline.net Message #991
From: Johan Nikolaou <nikolaou@algonet.se>
Subject: Hydraulic
Date: Fri, 30 Oct 1998 09:18:41 +0100
To: lancair.list@olsusa.com <lancair.list@olsusa.com>
         <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
          <<  Lancair Builders' Mail List  >>
          <<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
>>
As I earlier mentioned I had a few problems with my hyraulics that I
couldnīt figured out.

After the plane had been left for a few days either the pump went on
continiously or didn`t start at all. After cycling the gear or lettning
out som pressure by opening a line the system worked perfect until I
left it for a day or two.

I changed the lowpress switch to the new type and the fault was gone.

The new type of switch is mounted direct on the pump via a T fitting and
I think the pressure switches are of a better quality than the old type
so i changed the hi-press switch aswell.


SE-XPX