Right on Marv.
Here is a way to detect position on an LNC2 using the
linear flap positioning motor. A curved micro switch arm
rests in the groove that the stabilization rod runs in.
When the rod moves through the 1/3 flap position, the switch
is made and stays made until the flaps are retracted.
Grayhawk