Art writes <<My volt 1 circuit breaker off the field of the altenator
keeps tripping when I cycle the gear. This happens 100% of the time
when going up and 20% going down.>>
Art,
Here's another consideration. Heat. If I remember correctly,
B&C regulators have a max operating temp of 90C. If the regulator is
mounted on the engine compartment side of the fire wall, the temps can
easily exceed 90C. I lost a regulator for just such a situation so I added
a 3/4" blast tube from the back of the baffling to the regulator area for the
new one and that has lasted for years. I know the temp in that area
because I have a roaming CAT probe (display limit is 99C).
If it becomes true that temperature has damaged your regulator (after
performing B&C tests), install the new one inside the aircraft if at all
possible.
Scott Krueger