Posted for Sky2high@aol.com:
In this case the switch is mounted to detect the flap 2/3 extension position. The micro switch arm extends into the guidance rod channel and rides on the rod until the end passes and trips the switch. The sw is mounted on a wee angle secured to the device in the same manner as the magnetic limit switches. Were I to do it again for the 300 series, I would sense 1/3 flaps (15 degrees, 8 degrees out of reflex) and recalibrate) which would move the switch to the left about 1.5 inches. Note that a bit of the rod channel was ground out so that the micro sw arm would not hang up by contacting the channel sides. Scott Krueger AKA Grayhawk Lancair N92EX IO320 SB 89/96 Aurora, IL