Posted for "Gerard O Connell" <goconnell@dodo.com.au>:
Jim, I had a similar problem on the 320. I replaced the magnetic switches but
the problem continued. Several mechanics looked at the problem and whilst
releasing the flaps was no problem to them only one suggested a permanent
solution.
The solution was to place a bushing to stop the actuator getting "locked up".
I had a shop do the work but if the theory makes no sense I could organise a
photo.
I am unsure if the 320 and Legacy have the same mechanism?
--
Gerard O Connell
Melbourne, Australia
VH-LPD (LNC2)
"""
My ES has a little over 800 hours on it. In that time I have had
three
instances of being unable to retract the flaps from full extension. In
each
instance I was able to unhook the motor from the flaps and get it to
run. In
each instance I found that the motor had pulled the actuator rod past
the full
extension limit switch until it jammed inside the rod's housing and
popped the
circuit breaker.
When I pulled the pin out of the rod end the rod was very tight inside
the
housing. When I slightly rotated the rod it got free and the motor
would run
and move the actuator rod.
"""
|
|