Return-Path: Sender: (Marvin Kaye) To: lml@lancaironline.net Date: Fri, 19 Dec 2003 09:16:12 -0500 Message-ID: X-Original-Return-Path: Received: from [32.97.166.31] (HELO prserv.net) by logan.com (CommuniGate Pro SMTP 4.1.8) with ESMTP id 2895797 for lml@lancaironline.net; Thu, 18 Dec 2003 08:44:11 -0500 Received: from b8p5r1 (slip-12-64-198-61.mis.prserv.net[12.64.198.61]) by prserv.net (out1) with SMTP id <2003121813440920104jh453e>; Thu, 18 Dec 2003 13:44:09 +0000 From: "Larry Henney" X-Original-To: "'Lancair Mailing List'" Subject: RE: [LML] plenum to cowl connection X-Original-Date: Thu, 18 Dec 2003 07:43:42 -0600 X-Original-Message-ID: <007501c3c56c$f48c96a0$e9c6410c@b8p5r1> MIME-Version: 1.0 Content-Type: multipart/alternative; boundary="----=_NextPart_000_0076_01C3C53A.A9F226A0" X-Priority: 3 (Normal) X-MSMail-Priority: Normal X-Mailer: Microsoft Outlook, Build 10.0.2627 X-MimeOLE: Produced By Microsoft MimeOLE V6.00.2800.1165 Importance: Normal In-Reply-To: This is a multi-part message in MIME format. ------=_NextPart_000_0076_01C3C53A.A9F226A0 Content-Type: text/plain; charset="iso-8859-1" Content-Transfer-Encoding: 7bit Randy, I took old inner tubes and made sleaves out of them. Giant hose clamp on each end made for the attachment. Mine are unique in that they attach to rings that insert into the leading edge of the cowl halves. The plenum leading edge is also cylindrical. So if I'm hearing you correctly, you could do as the Greenamier Legacy is built. That is, have the lower cowl intake include the entire cylinder. This would allow proper attach to both cowl and plenum. Then the top cowl, using only a flange at the leading edge, could bolt on top. I found the plumbers tubes to be too stiff for my installation. A better installation would use the legs out of an old wet suit. Best, Larry Henney N360LH ------=_NextPart_000_0076_01C3C53A.A9F226A0 Content-Type: text/html; charset="iso-8859-1" Content-Transfer-Encoding: quoted-printable Message
Randy,
 
I took=20 old inner tubes and made sleaves out of them.  Giant hose clamp on = each end=20 made for the attachment.  Mine are unique in that they attach to = rings that=20 insert into the leading edge of the cowl halves.  The plenum = leading edge=20 is also cylindrical. 
 
So if=20 I'm hearing you correctly, you could do as the Greenamier Legacy is = built. =20 That is, have the lower cowl intake include the entire cylinder.  = This=20 would allow proper attach to both cowl and plenum.  Then the top = cowl,=20 using only a flange at the leading edge, could bolt on = top.
 
I=20 found the plumbers tubes to be too stiff for my=20 installation.
 
A=20 better installation would use the legs out of an old wet=20 suit.
 
Best,
 
Larry=20 Henney
N360LH
------=_NextPart_000_0076_01C3C53A.A9F226A0--