<< Lancair Builders' Mail List >>
<<<<<<<<<<<<<<<<--->>>>>>>>>>>>>>>>
>>
Posted for "Barrett/Burns" <2thman@olympus.net>:
Angier,
Although I have a IVP, vs a 360, I measured the area to bond and compared it
with manual recommendations for the flaps, because my manual hints at
approximate amounts needed for those surfaces. I then interpolated an
amount based upon the area to bond in the two cases.
What I failed to consider is that in the case of the flaps, there is a
release that insures a tight fit with minimal gaps at all joints. With the
windows, there are areas where the glue line will have significant dimension
and volume. If I were doing it again, I'd add 25% or so to fill the gaps.
Perhaps without pressurization, the appearance of voids in the joint won't
be as critical, but I'd think you want to be sure to get good squeezeout
anyway.
John Barrett
|
|