Return-Path: Received: from [24.50.193.34] (account ) by logan.com (CommuniGate Pro WebUser 4.0.5) with HTTP id 1991825 for ; Sat, 18 Jan 2003 00:31:06 -0500 From: "Marvin Kaye" Subject: Re: [Fwd: LNC2 Hyd. Power Pack] To: lml X-Mailer: CommuniGate Pro Web Mailer v.4.0.5 Date: Sat, 18 Jan 2003 00:31:06 -0500 Message-ID: In-Reply-To: <3E28C43B.9B188424@attbi.com> MIME-Version: 1.0 Content-Type: text/plain; charset="ISO-8859-1"; format="flowed" Content-Transfer-Encoding: 8bit Posted for "Angier M. Ames" : This sounds like good news... >From Vern at Lancair: Angier, If the spool valve is put in backwards, you would have low press. trying to raise the gear and the pump would probably not shut off very fast, and you would have high press snapping the gear down if the pump even came on. Nobody that has had the spool valve put in backwards has ever been charged for correcting it. I am not even involved in the process, you just contact Oildyne and send it directly to them. vern