Mailing List flyrotary@lancaironline.net Message #62307
From: Bobby J. Hughes <flyrotary@lancaironline.net>
Subject: Re: [FlyRotary] Re: What do you think may be happening?
Date: Wed, 20 Jan 2016 07:19:19 -0600
To: Rotary motors in aircraft <flyrotary@lancaironline.net>
Bill

Honeywell has a great switch selector / filter website complete with individual drawings. They have every connection option and contact orientation possible. Make sure to verify the contact orientation using the individual switch drawings.  Lots of options.  


Their switch filter does not work well with my iPad. 

Bobby

Sent from my iPad

On Jan 19, 2016, at 7:29 PM, Bill Bradburry <flyrotary@lancaironline.net> wrote:

Dennis,

 

I discovered today that my secondary injector disable switch was bad.  Flipping the switch gave no continuity either way.  After flipping it back and forth several times, it began to make a high resistance contact.  I guess the movement caused the contacts to clean off a little.

 

I am using the Carling S700 series switch espoused by Bob Nuckolls and sold by B & C.  This was a 2-3 switch that is double pole and is on-on.  These switches are pretty inexpensive…$7.50 each.  I was getting ready to  order a couple more switches and got to thinking about it.

 

The injectors pull pretty high amps I think pretty close to the switch capacity.  Does anyone know how many amps the injectors pull?

 

Is there a switch with pretty high capacity that is on-on with push tabs that I could substitute?

 

Bobby suggested some Honeywell switches but they are not on-on and don’t accept the push tabs.

 

Bill  

 


From: Rotary motors in aircraft [mailto:flyrotary@lancaironline.net]
Sent: Friday, January 15, 2016 10:44 PM
To: Rotary motors in aircraft
Subject: [FlyRotary] Re: What do you think may be happening?

 

What type of switch are you using to disable the primary and secondary injectors?  I was using  "rocker" switches and I found they failed to make good contact - failed  "open".  This would turn off the one set of injectors but not tell the computer to double the on time of the other injectors.  I replaced all my switches  rocker switches with "snapping" toggle switches.

 

I want to thank Steven Boese, Bobby Hughes and Mark Steitle for all their help in diagnosing this problem.

 

I never could make the switch fail during ground run testing!

 

Dennis H.

 