Ok, so
that means that they work essentially the same, except that a full
scale turn in either direction for the mode 1 makes a full scale rich or lean,
whereas the mode 9 is in a much smaller increment, but still proportional to
the amount the knob is turned, just not as much as in mode 1.
Not quite. In mode 1 the mixture
is changed in a step equal/proportional to the position of the Program
Value knob. Just push the store button once – repeated pushing of the store
button does nothing more – unless you reposition the Program Value knob.
It took me a long time to get that right.
You have mode 9 right – repeated pushes
of the Store button will step the mixture.
Mode 5 is used on my 3-rotor to adjust
the mixture of rotor 2, so I can adjust EGTs on 1 & 2 to be the same as 3. Not needed on
2-rotor.