Looking to design and build hangar doors.
I kinda fancy vertical harmonica doors.
/\/\/\/\/\
The inner points carried by wheels in groove in concrete slab.
Wheels able to pivot in bottom of door frames.
Top supported by rollers in a steel U-channel, able to pivot in top
of door frames.
I figure 3 feet wide sections hinged at edges.
The thinner the better, but will have to be able to withstand wind
pressure without deforming.
10 feet tall.
Max wind pressure 31 pounds/sq ft. (110 mph wind zone).
Obviously that's on the high side. There are trees in the vicinity.
So 20 pounds/sq ft may be a more realistic number. But it doesn't
hurt to be on the safe side,
For calculations the vertical supports will be spaced 1.5 feet
apart. (Actually 3 feet apart but doubled at each edge).
I'm figuring maximum of 450 pounds of distributed weight (wind
pressure) on each vertical support.
I've seen a couple of different formulas for maximum deflection, for
example:
5/384 * W * L^3 / (E * I).
I assume I can safely use E = 30,000,000 for steel.
Let's say I'll allow 3" maximum deflection:
I = 0.113?
However, I'm having trouble arriving at values for I (area moment of
inertia).
What would I be for a 2"x2" 1/8" wall square steel tube?
(2 * 2^3) / 12 = 1.33?
Or would that only be for a solid 2x2" bar?
For a 1.5" square tube?
I = 0.42?
(I also need guard railing for my porch. Seems a1.5"D tube with
1/8" wall is I = 0.1276.
Does that seem right?)
Also, I guess I'm not so much concerned with deflection as with
point of permanent deformation.
How would I arrive at that number?
My objective is the thin hangar doors and the lightest guard rails.
And of course cheapest materials.
Sanity check appreciated.
Finn