In a message dated 9/17/2007 7:54:05 PM Pacific Standard Time,
wdleonard@gmail.com writes:
Al,
I have the TWM at the end of long runners, and computer B
takes its manifold reading there. I also use the stock manifold that has
a port right as the mixture enters the center housing. Computer A takes
its manifold reading there. Besides a slight difference in the mixture
necessary between the 2 computers, both locations seem to work well.
Sorry I don't have a solution.
Dave
Leonard
Dave, Al,
I think you need the accumulator bottle. Use a container that will
tolerate full vacuum using a small opening plum some 1/8 ID lines to the bottle.
Nothing fancy just small diameter lines feeding a cannister. (about 1 pint size
would do. Put the vac sensor in or connected to the bottle. It will dampen the
pulses a great deal. use 2 (13B) or 3 (20B) lines to the manifold.
Bill Jepson
|
|