X-Virus-Scanned: clean according to Sophos on Logan.com
Return-Path: <jewen@comporium.net>
Received: from smtprh01.spirittelecom.com ([165.166.0.77] verified)
  by logan.com (CommuniGate Pro SMTP 5.1c.3)
  with ESMTPS id 1358819 for flyrotary@lancaironline.net; Thu, 31 Aug 2006 20:35:20 -0400
Received-SPF: pass
 receiver=logan.com; client-ip=165.166.0.77; envelope-from=jewen@comporium.net
X-Report-Abuse-To: abuse@spirittelecom.com
X-DKIM: Sendmail DKIM Filter v0.2.1 smtprh01.spirittelecom.com k810ZDDG012322
DKIM-Signature: a=rsa-sha1; c=nowsp/nowsp; d=comporium.net; s=spiritmail;
	t=1157070914; h=DomainKey-Signature:Message-ID:From:To:References:
	 Subject:Date:MIME-Version:Content-Type:Content-Transfer-Encoding:
	 X-Priority:X-MSMail-Priority:X-Mailer:X-MIMEOLE:X-Virus-Scanned:
	 X-Virus-Status; b=MMwx1LTbt/GlALofxRemR8lS4nsynCYXzsP5Aej2uUSacxKxo
	GFgx/hipdHQdilOW/uGOLj+Jfd5LFJdk7I9sA==
DomainKey-Signature: a=rsa-sha1; s=spiritmail; d=comporium.net; c=nofws; q=dns;
	h=message-id:from:to:references:subject:date:mime-version:
	content-type:content-transfer-encoding:x-priority:
	x-msmail-priority:x-mailer:x-mimeole:x-virus-scanned:x-virus-status;
	b=gsuoZ8lfWyk12pgfr3fPf9ttjq1CfM3Cb6w6d9TCiqxX5C2UEOB8CO/C8fGQeVg+F
	LpvSxqZHoScjMDvYTR1tw==
Received: from Engineer1 (208-104-88-189.lnhe.2wcm.comporium.net [208.104.88.189] (may be forged))
	by smtprh01.spirittelecom.com (8.13.6/8.13.1) with SMTP id k810ZDDG012322
	for <flyrotary@lancaironline.net>; Fri, 1 Sep 2006 00:35:14 GMT
Message-ID: <005901c6cd5e$69481770$6405a8c0@cooleygroup.local>
From: "Joe Ewen" <jewen@comporium.net>
To: "Rotary motors in aircraft" <flyrotary@lancaironline.net>
References: <list-1358244@logan.com>
Subject: Re: [FlyRotary] Re: EC2 Current Requirements
Date: Thu, 31 Aug 2006 20:34:39 -0400
MIME-Version: 1.0
Content-Type: text/plain;
	format=flowed;
	charset="iso-8859-1";
	reply-type=original
Content-Transfer-Encoding: 7bit
X-Priority: 3
X-MSMail-Priority: Normal
X-Mailer: Microsoft Outlook Express 6.00.2900.2869
X-MIMEOLE: Produced By Microsoft MimeOLE V6.00.2900.2962
X-Virus-Scanned: ClamAV 0.88/1783/Thu Aug 31 20:56:17 2006 on smtprh01.spirittelecom.com
X-Virus-Status: Clean

Al,
What type of 15A fuse did you blow?  Not all fuses are created equal.  There 
are different trip characteristics for use in different applications.   The 
first letter in the fuse number defines the trip characteristic for 6.am 
fuses.
A=Fast Blow                -Normally used on resistive loads that do not 
have inrush currents.  i.e. heaters, illumination.
G=Ultra Fast Blow        -Normally used on sensitive electronics.
M=Time delay                -Normally used on inductive loads to handle 
starting or inrush loads.  i.e. transformers, motors.

IMO time delay fuses should be used on the ignition coil circuits, they will 
better tolerate the inrush current as they are inductive loads.  Breakers 
are often available with different trip characteristic as well, depending on 
the breaker family.

I would not be suppressed in an application like you described if a AGC15 
would trip, but a MDA15 would hold.

Joe





----- Original Message ----- 
From: "Al Gietzen" <ALVentures@cox.net>
To: "Rotary motors in aircraft" <flyrotary@lancaironline.net>
Sent: Thursday, August 31, 2006 12:49 PM
Subject: [FlyRotary] Re: EC2 Current Requirements


I've designed in quite a bit of electrical dependancy, so the
alternator-out running time has me concerned.  With all injectors and
coils on seperate switches, it should be possible to extend the range by
switching off a set of injectors and the trailing coils, and accepting
reduced power.  Does that sound viable?
-------------

I guess you meant "electrical redundancy".

On my 20B install, a 15A fuse blew running 3 LS1 coils.  20A seems to be OK.

Does pulsing two injectors take more current than pulsing one injector twice
as long?

Al


--